DISCLAIMER AND WARNING
These instructions are provided as a general guide for installation. Vehicle configurations, wiring layouts, and mounting locations vary. The installer is responsible for verifying that all electrical and pneumatic connections are correct and safe for the specific vehicle.
Grover Products assumes no responsibility for damage, injury, or vehicle malfunction resulting from installation errors, incorrect wiring, improper component use, or reliance on these instructions without proper verification.
Sound levels of Grover®️air horns may exceed 120 dB and can cause permanent hearing loss. Minimize exposure and wear hearing protection. Do not sound indoors or in enclosed areas. Do not exceed 125 PSI.
INSTALLATION GUIDELINES
All installation and testing must be performed by qualified personnel familiar with automotive electrical and compressed air systems.
Disconnect the vehicle battery before beginning installation. Use thread sealant on all NPT fittings. Use tube supports on all compression fittings. Tighten all fittings securely to maintain an airtight system.
PNEUMATIC CONNECTIONS
Step 1. Compressor to Tank
Use the stainless braided leader hose supplied in the Viair compressor box. Thread the leader hose directly into any ¼ NPT port on the air tank. Do not remove the integrated check valve.
Step 2. Pressure Switch and air safety valve
Attach the ¼ pipe size Tee to any unused ¼ NPT port on the air tank. On one branch of the Tee, install the air safety valve to prevent over-pressurization. On the other branch install the pressure switch. The pressure switch must be wired to shut off the compressor at the rated cut-out pressure.
Step 3. Drain cock
Install the drain cock in the lowest ¼ NPT port on the air tank.
Step 4. Tank to 1136 Valve
On the final tank port, install a ¼ NPT male compression fitting with tube support. Run tubing from the tank to the “INLET” port on the 1136 valve using a ⅛ NPT male compression fitting and tube support.
Step 5. 1136 Valve to Horn
Install a ⅛ NPT female compression fitting on the 1136 “OUTLET” port. Connect tubing using tube support. Attach tubing to horn using ⅛ NPT male compression fitting and tube support.
ELECTRICAL CONNECTIONS
The compressor must be wired using a 30A automotive relay rated for continuous duty. Do not power the compressor directly through the pressure switch. Verify vehicle electrical system is 12V DC.
Step 1. Install a 30A fuse within 12 inches of battery positive terminal. Connect fused battery lead to relay terminal 30.
Step 2. Connect relay terminal 87 to compressor positive lead.
Step 3. Ground compressor negative to chassis.
Step 4. Wire the pressure switch between fused ignition or battery source and relay terminal 86.
Step 5. Connect relay terminal 85 to chassis ground.
Step 6. Wire the 1136 valve to the horn button using fused 12V power and ground per standard practice.
Step 7. Secure all wiring away from heat and moving components.
FINAL INSTALLATION
Mount compressor, tank, and horn securely using supplied hardware. Verify clearances from heat and moving components. Reconnect battery. Pressurize system and check for leaks before operation.